TM 9-2815-205-34
4-10. RUN-IN OF ENGINE (Cont)
(3) Air Correction Factor (CFa).
(a) Measure air inlet temperature (T) at air cleaner during test.
(b) Refer to Table 4-5, 4-6, or 4-7 of appropriate model for air correction factor (CFa) using air
inlet temperature (T) and dry barometric pressure (BAROd).
Table 4-5. Air Correction Factor (CFa) in BHP
Model 5063-5299
Dry Barometric Pressure - (BAROd) – inches Hg
24.00 25.00 26.00 27.0 0
28.00 28.50 29.00 29.50 30.0 0
T
60
8
6
4
3
1
0
0
-1
- 2
e
65
8
6
4
3
1
1
0
–1
- 2
m
70
8
6
5
3
2
1
0
–1
–1
P
75
9
7
5
3
2
1
0
0
-1
e
80
9
7
5
4
2
1
1
0
–1
r
85
9
7
6
4
2
2
1
0
0
a
90
9
8
6
4
3
2
1
0
0
t
95
10
8
6
5
3
2
1
1
0
u
100
10
8
6
5
3
2
2
1
0
r
105
10
8
7
5
3
3
2
1
1
e
110
10
9
7
5
4
3
2
2
1
115
11
9
7
6
4
3
3
2
1
T
120
11
9
7
6
4
4
3
2
1
125
11
9
8
6
5
4
3
2
2
°F
4-46