TM 9-2815-205-34
Table 4-6, Air Correction Factor (CF
a
) in BHP
Models 5063-5392, 5063-5393 and 5063-539L
Dry Barometric Pressure - (BARO
d
) - inches Hg
24.00 25.00 26.00 27,0 0
28.00 26.50 29.00 29.50 30.0 0
T
60
6
4
3
1
0
-1
- 2
- 2
- 3
e
65
6
5
3
2
0
0
-1
- 2
- 2
m
70
7
5
4
2
1
0
0
-1
- 2
P
75
8
6
5
3
2
1
0
0
-1
e
80
8
7
5
4
2
2
1
0
0
r
85
9
7
6
4
3
2
2
1
0
a
90
10
8
6
5
3
3
2
1
1
t
95
10
9
7
6
4
3
3
2
1
u
100
11
9
8
6
5
4
3
3
2
r
105
11
10
8
7
5
5
4
3
3
e
110
12
10
9
7
6
5
5
4
3
115
13
11
9
8
6
6
5
4
4
T
120
13
12
10
8
7
6
6
5
4
125
14
12
11
9
8
7
6
6
5
“F
Table 4-7, Air Correction Factor (CF
a
) in BHP
Models 5063-5395, 5063-5398, and 5063-539F
Dry Barometric Pressure - (BARO
d
) - inches Hg
24.00 25.00 26.00 27,0 0
28,00 28.50 29.00 29.50 300 0
T
60
6
5
3
1
0
-1
- 2
- 2
- 3
e
65
7
5
4
2
0
0
-1
- 2
- 2
m
70
8
6
4
3
1
0
0
-1
- 2
P
75
8
7
5
3
2
1
0
0
-1
e
80
9
8
6
4
3
2
1
0
0
r
85
10
9
7
5
4
3
2
2
1
a
90
11
9
8
6
4
3
3
2
2
t
95
11
9
8
6
4
3
3
2
2
u
100
12
10
8
7
5
4
4
3
2
r
105
12
11
9
7
6
5
4
4
3
e
110
13
11
10
8
6
5
5
4
3
115
14
12
10
9
7
6
6
5
4
T
120
14
13
11
9
8
6
6
5
5
125
15
13
12
10
8
7
7
6
5
°F
Change 1
4-47