TM 9-2815-210-34-2-2
FRAME 14
1.
2.
3.
4.
5.
6.
Measure
Measure
Measure
Measure
Measure
Measure
NOTE
Readings must be within limits given in table 4-34. The
letter L shows a loose fit. If readings are not within
given limits, get a new oil pump.
inside diameter of driven impeller bushing (1).
outside diameter of driven impeller shaft (2).
fit of driven impeller shaft (2) in driven impeller bushing (1).
depth of pressure pump driven impeller bore (3).
length A of pressure pump driven impeller (4).
clearance between pressure pump driven impeller
pressure pump drive impeller bore (3).
-
GO TO FRAME 15
(4) and top of