TM 9-2815-210-34-2-2
4-74. FLAME HEATER IGNITION UNIT (SIDE-MOUNTED SYSTEM).
For procedures
to repair the flame heater side-mounted ignition unit, refer to flame heater ignition
unit (covered system), para 4-65c.
4-75. FLAME HEATER WIRING HARNESS AND ELECTRICAL LEAD ASSEMBLY (SIDE-
MOUNTED SYSTEM).
For procedures to repair the side-mounted heater wiring
harness, refer to covered flame heater wiring harness, para 4-67b.
4-76. FLAME HEATER NOZZLE AND VALVE ASSEMBLY (SIDE-MOUNTED SYSTEM).
a .
Cleaning and Inspection.
FRAME 1
1.
2.
3.
4.
5.
Leave felt fuel line filters in fuel inlet (1) and outlet (2) openings in place.
Plug nozzle and valve assembly fuel inlet (1) and outlet (2) openings with
plugs.
WARNING
Dry cleaning solvent is flammable. Do not use
near an open flame.
Keep a fire extinguisher
nearby when solvent is used. Use only in well-
ventilated places.
Failure to do this may result
in injury to personnel and damage to equipment.
Clean nozzle and valve assembly (3) with dry cleaning solvent. Take off
heavy carbon deposits with a stiff brush.
pipe
Check that nozzle and valve assembly fuel inlet (1) and fuel outlet (2) threads
are not crossthreaded.
Check that nozzle and valve assembly (3) is not cracked or damaged. Get a
new nozzle and valve assembly if it is cracked or damaged.
END OF TASK