TM-9-2815-220-24

AVDS-1790 2CA, 2DA and 2DR Air-Cooled 12-Cylinder Diesel Engines

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL FOR AVDS-1790 2CA, 2DA and 2DR Air-Cooled 12-Cylinder Diesel Engines

  TM-9-2815-220-24 - Page 288 of 1563

TM 9-2815-220-24
ENGINE RUN-IN
0044 00
WP 0044 00-2
BEFORE RUN-IN (Continued)
5.
Provide a suitable external source of 24-volt, direct current, electrical power for starting the
engine.
NOTE
The engine is equipped with a low-voltage protective module so
starter will not operate below 12 volts.
U
CAUTION
On engines (all 2CAs and some 2DAs) with a 650-amp generator, it
will be necessary to load the generator to 50 amperes or damage to the
generators drive clutch will occur.
6.
Connect generator to voltage regulator and batteries as shown.
VOLTAGE
REGULATOR
650AMPERE
GENERATOR