TM 9-2815-224-34&P
Blower and Water Pump Drives Maintenance Instructions (Cont)
10-40 BLOWER DRIVE SEAL RING REMOVAL/INSTALLATION (CONT).
(3)
(4)
(5)
(6)
(7)
Install blower drive seal ring (1) on blower drive (3)
with cement coated cut end (2) on top.
Slide other cut end of blower drive seal ring (1) up to
mate with cement coated end.
Hold joined ends of blower drive seal ring (1)
together for 30 seconds.
Position seal ring clamp (4) between raised edges of
blower drive seal ring (1).
Tighten seal ring clamp (4).
c. Follow-on Maintenance.
(1) Start engine (TM 9-2320-279-10).
(2) Let engine idle for three or four minutes. Then check around blower drive seal ring for oil leaks.
(3) Install engine cover (TM 9-2320-279-20).
END OF TASK
Section Ill.
WATER PUMP DRIVE GEAR ASSEMBLY
10-5. WATER PUMP DRIVE GEAR REMOVAL/INSTALLATION.
This task covers:
I
a. Removal
c. Follow-on Maintenance
b. Installation
INITIAL SETUP
Models
All
Test Equipment
None
Special Tools
None
Supplies
None
Personnel Required
MOS 63W, Wheel vehicle repairer
References
None
Equipment Condition
TM or Para
Condition Description
Para 7-12
Front balance cover
removed.
Special Environmental Conditions
None
General Safety Instructions
None
Level of Maintenance
Direct Support
10-12