TM 9-2920-225-34
FRAME 4
I
1.
Check that stator (1) is not cracked or broken. If stator is damaged,
generator is nonrepairable.
2.
Using multimeter, check stator (1) for continuity.
Touch test probes of
multimeter to each pair of stator leads
(
2). Multimeter
must show low
resistance.
If it does not, generator is nonrepairable.
3.
Using multimeter, check stator (1) for grounds. Touch
one test
probe to
stator and other test probe to each stator lead (2) . If stator is grounded,
generator is nonrepairable.
GO
TO
FRAME 5
TA10353 1
2-31