5920-01-644-4286

ARRESTER,ELECTRICAL SURGE


5920-01-644-4286 (5920016444286, 016444286)
Part Number (1 listing): SP075A
Summary

FSG 59 / FSC 5920

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 5 May 2015

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5920-01-644-4286 Submit RFQ
Manufacturer Part Number RNCC RNVC Manufacturer Name CAGE
SP075A 3 - Design Control Reference 2 - Production Item BLACK BOX CORPORATION OF   59951     CAGE 59951  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5920-01-644-4286 Submit RFQ
FSG FSC NIIN FIIG INC CRITICALITY TYPE OF ITEM MRC DEMIL HMIC EDC PMIC ADPEC DATE CREATED
59 5920 016444286 T214-C 00381 X 4 3 A P A A 0 5 May 2015
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5920

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Fuses, Arrestors, Absorbers, and Protectors

016444286

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5920-01-644-4286

T214-C

Federal Item Identification Guide (FIIG_4065)

00381

Item Naming Code (INC_4080)

5 May 2015

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5920-01-644-4286 Submit RFQ
MOE Rule Former MOE AMC AMSC NIMSC IMC IMC Activity AAC DSOR Collaborators Receivers Effective Date
MC49 3 Z Z PA 1 May 2015
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

Z

Acquisition Method Suffix Code (AMSC_2876)


This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

PA

Item Management Coding Activity (IMC_ACTY_2748)


Marine Corps Logistics Base, Albany, GA 31704-1128


FLIS - SEG C - REFERENCE NUMBER | NSN 5920-01-644-4286 Submit RFQ
RNFC RNCC RNVC DAC RNAAC RNSC RNJC SADC MSDS HCC Reference Number CAGE
3 2 3 ZZ SP075A   59951   CAGE/59951
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG G - FREIGHT DATA | NSN 5920-01-644-4286 Submit RFQ
Integrity Originating HMC LCL WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
PA 658 Z 9 A H Z P 062380 X 34900 LIGHTNING-ARRESTERS-PARTS-NOI
Code Definitions

PA

Originating Activity Code (ORIG_ACTY_CD_4210)


Marine Corps Logistics Base, Albany, GA 31704-1128

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

062380

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34900

Uniform Freight Classification (UFC_CD_MODF_3040)

LIGHTNING-ARRESTERS-PARTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5920-01-644-4286 Submit RFQ
Unit Price MOE SOS AAC CIIC QUP Reparability UI SLC
DM SMS Z Y 1 Z EA 0
DS SMS Z Y 1 N EA 0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

Y

Controlled Item Inventory Code (CIIC_2863)


Communication/electronic equipment and parts

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5920-01-644-4286 Submit RFQ
MRC Decoded Requirement Clear Text Reply
AAFZ Body Material PLASTIC
AQAQ Breakdown Voltage 60.0 VOLTS NOMINAL
AGAV End Item Identification 4940-01-551-2884; AN/TSM-214A
ALGC Mounting Configuration FREESTANDING, MAY BE MOUNTED VIA CLAMPING DEVICE
ADJH Mounting Method CASE
AWJN Unpackaged Unit Weight 0.218 POUNDS
ALCD Usage Design PROTECT WIRELESS ACCESS POINTS FROM DAMAGING POWER TRANSIENTS AND SURGES. PROTECT DATA LINES FOR BOTH LINE-TO-LINE AND GROUND-TO-LINE SURGES
ABFY Overall Depth 5.0 INCHES NOMINAL
ABKW Overall Height 2.0 INCHES NOMINAL
ABMK Overall Width 3.0 INCHES NOMINAL
CXCY Part Name Assigned By Controlling Agency POWER OVER ETHERNET SURGE PROTECTOR, 60-VOLT
FEAT Special Features PINS 1, 2, 3, AND 6: PEAK PULSE CURRENT 10/100 WAVEFORM: 132 AMPS PROTECTION DIFFERENTIAL AND COMMON MODE RESPONSE TIME <5 NS SHUNT CAPACITANCE (MAXIMUM) <25 PF STANDARD CLAMPING VOLTAGE 7.5 VOLTS PINS 4, 5, 7, AND 8: PEAK PULSE CURRENT 10/100 WAVEFORM: SP075A: 50 AMPS; PROTECTION DIFFERENTIAL AND COMMON MODE, LINE TO GROUND RESPONSE TIME <5 NS STANDARD CLAMPING VOLTAGE 60 VOLTS
ALBY Usage Design INDOOR
AARA Terminal Quantity 3
AARB Terminal Type CONNECTOR, PLUG AND WIRE LEAD


Back to Top
Back to Top