6140-01-655-9210

BATTERY ASSEMBLY


6140-01-655-9210 (6140016559210, 016559210)
Part Number (1 listing): LI18S-5200
Summary

FSG 61 / FSC 6140

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 10 Jun 2016

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6140-01-655-9210 Submit RFQ
Manufacturer Part Number RNCC RNVC Manufacturer Name CAGE
LI18S-5200 3 - Design Control Reference 2 - Production Item ENERTECH INTL INC   00DZ7       
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6140-01-655-9210 Submit RFQ
FSG FSC NIIN FIIG INC CRITICALITY TYPE OF ITEM MRC DEMIL HMIC EDC PMIC ADPEC DATE CREATED
61 6140 016559210 T139-B 00152 X 1 A P A A 0 10 Jun 2016
Code Definitions

61

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electric Wire, and Power and Distribution Equipment

6140

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Batteries, Rechargeable

016559210

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6140-01-655-9210

T139-B

Federal Item Identification Guide (FIIG_4065)

00152

Item Naming Code (INC_4080)

10 Jun 2016

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6140-01-655-9210 Submit RFQ
MOE Rule Former MOE AMC AMSC NIMSC IMC IMC Activity AAC DSOR Collaborators Receivers Effective Date
ZK01 1 Jun 2016
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6140-01-655-9210 Submit RFQ
RNFC RNCC RNVC DAC RNAAC RNSC RNJC SADC MSDS HCC Reference Number CAGE
4 3 2 4 9Z D LI18S-5200   00DZ7  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 6140-01-655-9210 Submit RFQ
Integrity Originating HMC LCL WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
Code Definitions

X2

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6140-01-655-9210 Submit RFQ
MRC Decoded Requirement Clear Text Reply
AEXR Battery Quantity 1
AQHK Component Controlling Agency ENERTECH INTERNATIONAL INC.
AQHM Component Identifying Number LI8S-5200 PART NO.
AQHL Component Name LI8S-5200
ABKW Overall Height 20.5 MILLIMETERS NOMINAL
ABHP Overall Length 145.0 MILLIMETERS NOMINAL
ABMK Overall Width 37.5 MILLIMETERS NOMINAL
CXCY Part Name Assigned By Controlling Agency RECHARGEABLE LI-ION BATTERY PACK
FEAT Special Features CAPACITY 5200MAH NOMINAL; 4900MAH MINIMUM; 7.2V NOMINAL; CHARGING METHOD CC -CV CONSTANT-VOLTAGE WITH LIMITED CURRENT; CHARGING VOLTAGE 8.4?0.05V; CHARGING CURRENT 2600MA STANDARD; CHARGING CURRENT CUT -OFF <260MA; DISCHARGE CURRENT 1040MA, 2600MA CONTINUOUS; DISCHARGE CUT-IFF VOLTAGE 6.0V; INTERNAL RESISTANCE <300 MILIOHMS; OPERATING TEMPERATURE 15-40 C STANDARD CHARGE, -20 TO 55 C STANDARD DISCHARGE; STORAGE TEMPERATURE 0 TO 25C <1 YEAR, 0 TO 45C < 3 MONTHS, 0 TO 60C < 1 MONTH


Back to Top