Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MA300-5CH-0.3UM-10.0UM-220V | 3 - Design Control Reference | 2 - Production Item | HACH ULTRA ANALYTICS INC. | 53882 | ![]() |
MA300-5CH-0.3UM-10.0UM-220V | 3 - Design Control Reference | 9 - No Longer Used | PACIFIC SCIENTIFIC SERVICE INC | 1C3U7 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 6635 | 014642249 | T398-G | 19248 | X | 1 | A | N | A | A | 0 | 21 Apr 1999 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or
application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZS01 | 1 Apr 1999 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | 9Z | MA300-5CH-0.3UM-10.0UM-220V | 53882 |
![]() |
||||||
4 | 3 | 9 | 4 | 9Z | D | MA300-5CH-0.3UM-10.0UM-220V | 1C3U7 |
![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
DLIS-K, Battle Creek, MI 49037-3084
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 21 Apr 1999 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents
your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction.
Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
50 |
Department of Labor-Job Corp, Washington, DC 20213
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ACDC | Current Type | AC |
ELEC | Voltage In Volts | 220.0 |
FREQ | Frequency In Hertz | 50.0 |
FEAT | Special Features | FLOW RATE: 1 CUBIC FOOT PER MINUTE; ZERO COUNTS: < 1 COUNT IN 60 MINUTES; COINCIDENCE LOSS: < 5 PERCENT AT 200.000 PARTICLES/FT CUBED; DISPLAY: LED; LIGHT SOURCE: LASER DIODE; SAMPLE TIME: 1 SECOND TO 24 HOURS; SAMPLE HOLD TIME: 1 SECOND TO 24 HOURS; OUTPUTS: RS232/RS485; DATA STORAGE; 400 SAMPLES; BUILT-IN PRINTER; CHANNELS: 5; SENSITIVITY: 0.3 OR 0.5UM; SIZE OF CHANNELS: 0.3, 0.5, 1.0, 5.0, AND 10.0UM; COUNTS TWO OR MORE SIZES SIMULTANEOUSLY; CAPABLE OF STORING UP TO 400 READINGS; FEDERAL STANDARD 209E CALCULATION |
FTLD | Functional Description | USED IN CLEAN ROOM ENVIRONMENTS TCOUNT PARTICLES IN THE AIR |