6695-01-643-8436

TRANSDUCER,MOTIONAL PICKUP


6695-01-643-8436 (6695016438436, 016438436)
Part Number (1 listing): RPV0250MD601A01
Summary

FSG 66 / FSC 6695

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 14 Apr 2015

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6695-01-643-8436 Submit RFQ
Manufacturer Part Number RNCC RNVC Manufacturer Name CAGE
RPV0250MD601A01 3 - Design Control Reference 2 - Production Item MTS SYSTEMS CORPORATION   58830       
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6695-01-643-8436 Submit RFQ
FSG FSC NIIN FIIG INC CRITICALITY TYPE OF ITEM MRC DEMIL HMIC EDC PMIC ADPEC DATE CREATED
66 6695 016438436 T145-B 61282 X 4 3 A N A 0 14 Apr 2015
Code Definitions

66

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Instruments and Laboratory Equipment

6695

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Combination and Miscellaneous Instruments

016438436

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6695-01-643-8436

T145-B

Federal Item Identification Guide (FIIG_4065)

61282

Item Naming Code (INC_4080)

14 Apr 2015

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 6695-01-643-8436 Submit RFQ
MOE Rule Former MOE AMC AMSC NIMSC IMC IMC Activity AAC DSOR Collaborators Receivers Effective Date
ZH01 1 Apr 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 6695-01-643-8436 Submit RFQ
RNFC RNCC RNVC DAC RNAAC RNSC RNJC SADC MSDS HCC Reference Number CAGE
4 3 2 E 9Z D RPV0250MD601A01   58830  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 6695-01-643-8436 Submit RFQ
Integrity Originating HMC LCL WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
ZH
Code Definitions

ZH

Originating Activity Code (ORIG_ACTY_CD_4210)


Republic of Korea

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6695-01-643-8436 Submit RFQ
MRC Decoded Requirement Clear Text Reply
ACDC Current Type DC
CXCY Part Name Assigned By Controlling Agency SENSOR, NON-CONTACT POSITION
ABHP Overall Length 250.0 MILLIMETERS NOMINAL
FEAT Special Features OPERATING CONDITIONS: MAGNET SPEED: ANY, OPERATING TEMPERATURE: -40 - +75 C, DEW POINT, HUMIDITY: 90% REL. HUMIDITY, NO CONDENSATION, DESIGN MATERIAL: SENSOR HEAD AND SENSOR STROKE: ALUMINUM, ROD WITH FLANGE: STAINLESS STEEL 304, PRESSURE RATING: 350 BAR FOR HYDRAULIC ROD, POSITION MAGNET: MOUNTING PLATE AND SCREWS FROM ANTIMAGNETICAL MATERIAL, CONNECTION TYPE: 6-PIN CONNECTOR M16, POLARITY PROTECTION: UP TO -30 VDC, OVERVOLTAGE PROTECTION: UP TO 36 VDC, CURRENT DRAIN: 100MA TYPICAL, RIPPLE; <0.28VPP, ELECTRIC STRENGTH: 500 VDC (DC GROUND TO MACHINE GROUND).
AMSE Voltage Rating 24.0 VOLTS NOMINAL
AARB Terminal Type CONNECTOR, RECEPTACLE


Back to Top