7050-01-644-3252

CONVERTER,DIGITAL TO DIGITAL


7050-01-644-3252 (7050016443252, 016443252)
Part Number (1 listing): 2861-003
Summary

FSG 70 / FSC 7050

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 30 Apr 2015

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 7050-01-644-3252 Submit RFQ
Manufacturer Part Number RNCC RNVC Manufacturer Name CAGE
2861-003 3 - Design Control Reference 2 - Production Item DOWSLAKE MICROSYSTEMS CORPORATION   49CS0       
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 7050-01-644-3252 Submit RFQ
FSG FSC NIIN FIIG INC CRITICALITY TYPE OF ITEM MRC DEMIL HMIC EDC PMIC ADPEC DATE CREATED
70 7050 016443252 A508L0 60309 X 4 3 A N A 0 30 Apr 2015
Code Definitions

70

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Automatic Data Processing Equipment (Including Firmware), Software, Supplies and Support Equipment

7050

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


ADP Components

016443252

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 7050-01-644-3252

A508L0

Federal Item Identification Guide (FIIG_4065)

60309

Item Naming Code (INC_4080)

30 Apr 2015

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 7050-01-644-3252 Submit RFQ
MOE Rule Former MOE AMC AMSC NIMSC IMC IMC Activity AAC DSOR Collaborators Receivers Effective Date
ZG01 1 Apr 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 7050-01-644-3252 Submit RFQ
RNFC RNCC RNVC DAC RNAAC RNSC RNJC SADC MSDS HCC Reference Number CAGE
4 3 2 E 9Z D 2861-003   49CS0  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 7050-01-644-3252 Submit RFQ
Integrity Originating HMC LCL WCC TCC SHC ADC ACC ASH LTL NMFC NMFC Sub Item UFC Freight Description Rail Variance
CX
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 7050-01-644-3252 Submit RFQ
MRC Decoded Requirement Clear Text Reply
CXCY Part Name Assigned By Controlling Agency MODULAR COPPER CONVERTER FOR FRACTIONAL E1/T1
ABKW Overall Height 30.0 MILLIMETERS NOMINAL
ABHP Overall Length 190.0 MILLIMETERS NOMINAL
ABMK Overall Width 130.0 MILLIMETERS NOMINAL
CPLR Unit Design RACK MOUNTED
CSBH Voltage In Volts And Current Type 230.0 AC OR 115.0 AC
FEAT Special Features X.21 V.35 ETHERNET BRIDGE.EQUIPED WITH ETHERNET MODULE VT100 VIA SINGLE SLOT HOUSING,SNMP VIA MACS4000 AGENT VIA CERTAIN TIMESLOT,SA4 BITS OR UNFRAMED LINE 4;VIA VT100 OR SNMP/TELNET LINE QUALITY SUPERVISION FOR ALL G.704 INTERFACES BER TEST,SELF-TEST,LOOPS TERMINAL AND FACILITY LOOP PER PORT INTERNAL,EXTERNAL,REMOTE/SINGLE,DUAL ACC. ITU-T K20 AND ITU-TK21<77W;POWER SUPPLY: 230/115 VAC OR 48 VDC