2626
Use control box
J1 connector cap
If the cap for the W5P3 connector
disappears, dirt can plug the connector
fast. There is no replacement cap.
Solution: Use a cap for the control
box J1 connector. NSN 5935-01-195-
2337 gets the
cap for $6.
Tape a plastic
bag over the
connector
until the cap
comes.
Check that the rocket release catch
is on the front of the launcher arm stop.
If it’s on the rear of the stop, the rock-
ets fire but stay on the launcher. One
MICLIC crew suffered burns when that
happened.
W3
W5
Release
catch
should
be at
front
of stop
remember,
pm
is the
path
to
success
!
around and suffer damage. Gently bend
the guides back in place.
Make
sure
rocket
guides
are not
pointing
outward
RIGHT
WRONG
Store control
box and cables
inside storage box
W6
When the MICLIC is going to sit for
days, remove the W3,W5,
and W6 cables and the
control box and put them
in the storage box. Left
exposed to heat and
cold, the cannon wires
can separate from the
cannon plug. Just
the W3 cable
alone costs
more than
$1,200.
Storage


Back to Top