MWO 9-2300-378-34-2
Figure 32.
Hydraulic Pump and Smoke Generator Switch Brackets Mounted to Gage Indicator
Panel (used on vehicles equipped with M-9 Bulldozer)
(17) Secure harness receptacle connectors and excess cable at the relay with two tie
straps MS3367-6-9 (figure 28, view C).
(18) Disconnect the three harness securing straps back from bulkhead disconnects.
(19) Disconnect starter cable connector at the bulkhead (figure 28, view D).
(20) Back off retaining nut from plug assembly and remove existing rubber filler plug
and contact from location “A” (figure 28, view D).
(21) Install socket contact end of lead assembly 12290435 through retaining nut and
into hold position “A” (figure 28, view D). To aid in installation, lube socket and grommet hole
with silicone compound MIL-S-8660. Assemble retaining nut to plug assembly.
(22) Remove and discard existing identification band (harness part. no. 11673827) from
starter harness (figure 28, view D).
(23) Stamp harness part number 12290437 into new identification band MS43436/1-3
and apply to starter harness (figure 28, view D).
(24) Reconnect starter cable connector to bulkhead and connect single lead of harness
112270526 to lead assembly 12290435 (figure 28, view D). Use silicone compound if needed.
(25) Secure single lead of smoke harness with the
existing
securing straps.
NOTE
Check harness routing and connections to insure a neat
and secure installation.
44