MWO 9-2300-378-34-2
Figure 23. Installing Solenoid Positive Lead in Starter Harness/Receptacle
(20) Secure positive starter harness receptacle to bracket 12254374 with four screws
MS35265-63, lockwashers MS35338-43, and nuts MS35649-202 (figure 24).
(21) Install clamp MS21333-108 on solenoid positive lead and secure with one screw
and lockwasher removed instep 13 (figure 24). This screw also secures bracket 12254374.
(22) Connect cable connector to low voltage protection module (figure 25).
(23) Secure starter cables and low voltage module harness to engine oil cooler with
strap 11684276-2,
clamp MS21333-125,
screw MS90726-4, screw MS90726-3, and two
lockwashers MS35338-44 (figure 25).
NOTE
Check all fuel line connections to insure they are tight.
Inspect wiring for neat and secure routing.
Insure
solenoid lead has not been damaged in any way during
installation.
35