MWO-9-2300-378-34-2

TANK, COMBAT FULL-TRACKED

MODIFICATION WORK ORDER

JUNE 1984

  MWO-9-2300-378-34-2 - Page 28 of 92

MWO 9-2300-378-34-2
(5) Position shut-off valve bracket 12275809 to shroud and secure with two screws
192417 (figure 16).
CAUTION
T
O
prevent damage to vent line, due to rubbing, be sure
vent line does not contact top of bracket.
(6) Reposition oil cooler vent line elbow and oil cooler vent line so vent fine will clear
top of bracket 12275809.
Tighten oil cooler vent line elbow and screws securing clamps
(figure 16).
(7) Install manual shut-off valve 11669749 on bracket 12275809 with two screws
MS90726-7 and two nuts MS21045-4 (figure 16).
Figure 16.
Manual Shut-off Valve Installation
26


Back to Top