TB-9-2320-280-35-14

TECHNICAL BULLETIN

INSTALLATION INSTRUCTIONS FOR SINGLE CHANNEL GROUND AND AIRBORNE RADIO SYSTEM (SINCGARS) AN/VRC-88F, AN/VRC-89F, AN/VRC-90F, AN/VRC-91F, AN/VRC-92F

SEPTEMBER 2006

  TB-9-2320-280-35-14 - Page 84 of 148

5-62
TB 9-2320-280-35-14
Figure 5-83.
Section XXIV. EPLRS CABLES INSTALLATION (TWO-MAN VEHICLES)
NOTE
• Loosen right-side tunnel insulation before performing step 24-1.
(Refer to TM 9-2320-280-20.)
• Perform following procedures for two-man vehicle configuration
only.
24-1.
Route power cable (15) under right-side tunnel insulation towards terminal board. (Refer to
figure 5-84.)
24-2.
Attach heat shrink tubing (3) and two terminal lugs (1) and (8) to power cable negative lead (7) and
power cable positive lead (4). (Refer to TM 9-2320-280-20 for terminal connector repair.)
24-3.
Connect power cable positive lead (4) to 24V terminal board (10) located on cab
enclosure panel (11) with existing nut (2).
24-4.
Connect power cable negative lead (7) to ground strap (9) located on cab enclosure panel (11) with
existing nut (6). Secure leads together with tiedown strap (5).
24-5.
Secure right-side tunnel insulation. (Refer to TM 9-2320-280-20.)
1. TERMINAL LUG – 7728780 – QTY. 1
3. SHRINK TUBING – MS23053/4-302-0 – QTY. A/R
5. TIEDOWN STRAP – MS3367-1-0 – QTY. A/R
8. TERMINAL LUG – 7728777 – QTY. 1
11
1
2
5
3
4
~
6
7
3
8
9
10


Back to Top