Source Code.
The source code tells you how to get an item needed for maintenance, repair, or overhaul of
an end item/equipment. Explanations of source codes follow:
NOTE
Cannibalization of controlled exchange, when authorized, may be used as a source of supply for items with
the above source codes, except for those source coded “XA” or those aircraft support items restricted by
requirements of AR 750-1.
Code
Application/Explanation
PA
PB
PC
PD
PE
PF
PG
Stocked items; use the applicable NSN to request/requisition items with these
source codes. They are authorized to the maintenance category indicated by the
code entered in the third position of the SMR code.
Items coded PC are subject to deterioration.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KD
KF
KB
Items with these codes are not to be requested/requisitioned individually. They are
part of a kit which is authorized to the maintenance level indicated in the third posi-
tion of the SMR code. The complete kit must be requisitioned and applied.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MO - Made at Unit/
AVUM level
MF - Made at DS/AVIM Level
MH - Made at GS Level
ML - Made at SRA
MD - Made at Depot
Items with these codes are not to be requested/requisitioned individually. They must
be made from bulk materiel which is identified by the part number in the
DESCRIPTION AND USABLE ON CODE (UOC) column and listed in the bulk
materiel group work package of the RPSTL. If the item is authorized to you by the
third position of the SMR code, but the source code indicates it is made at a higher
level, order the item from the higher level of maintenance.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AO-Assembled by Unit/
AVUM level
AF-Assembled by DS/
AVIM level
AH-Assembled by
GS level
AL-Assembled by SRA
AD-Assembled by Depot
Items with these codes are not to be requested/requisitioned individually. The parts
that make up the assembled item must be requisitioned or fabricated and assembled
at the level of maintenance indicated by the source code. If the third position of the
SMR code authorizes you to replace the item, but the source code indicates the item
is assembled at a higher level, order the item from the higher level of maintenance.
XA
XB
XC
XD
Do not requisition an “XA” coded item. Order the next higher assembly. (Refer to
NOTE below).
If an item is not available from salvage, order it using the CAGEC and P/N.
Installation drawings, diagrams, instruction sheets, field service drawings; identi-
fied by manufacturer’s P/N.
Item is not stocked. Order an XD-coded item through normal supply channels using
the CAGEC and P/N given, if no NSN is available.