TB 9-2320-302-13&P-3
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
0009 00-5
Outside of
Cab Left
Side
3
Weekly
Receiver/
Dryer Unit
a. Inspect receiver/dryer unit for dam-
aged and loose or missing mounting
hardware.
Receiver/dryer unit is damaged or has
loose or missing mounting hardware
and A/C is required for mission.
b.Inspect receiver/dryer unit for leaks.
Leaks can be identified by oil residue
on fittings.
Leaks are evident and A/C is required
for mission.
c.Inspect A/C hoses and electrical har-
ness for damage and loose or missing
mounting hardware.
A/C hoses or electrical harness are dam-
aged or have loose or missing mounting
hardware and A/C is required for mis-
sion.
d.Inspect A/C hoses for leaks. Leaks
can be identified by oil residue on fit-
tings or along hose.
Leaks are evident and A/C is required
for mission.
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) - Continued.
Item
No.
Interval
Location
Procedure
Not Fully Mission
Capable If:
Item To
Check/
Service
449-053
RECEIVER/DRYER
ELECTRICAL HARNESS
A/C HOSES AND FITTINGS