TB 9-2320-302-13&P-3
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
0009 00-8
END OF WORK PACKAGE
5
Weekly
Condenser
a. Hood opened (TM 9-2320-363-10).
b.Inspect condenser for damage and
loose or missing mounting hardware.
Condenser is damaged, or mounting
bolts are loose or missing and A/C is
required for mission.
c.Inspect condenser for leaks. Leaks can
be identified by oil residue on fittings
or on condenser core.
Leaks are evident and A/C is required
for mission.
d.Inspect A/C hoses for damage and
loose or missing mounting hardware.
A/C hoses are damaged or have loose or
missing mounting hardware and A/C is
required for mission.
e.Inspect A/C hoses for leaks. Leaks
can be identified by oil residue on fit-
tings or along hose.
Leaks are evident and A/C is required
for mission.
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) - Continued.
Item
No.
Interval
Location
Procedure
Not Fully Mission
Capable If:
Item To
Check/
Service
449-056
A/C HOSES AND FITTINGS
CONDENSER