TB 9-2320-302-13&P-3
A/C AIR FILTER REPLACEMENT - CONTINUED
0010 00
0010 00-2
REMOVAL
WARNING
•
If NBC exposure is suspected, personnel wearing protective equipment should handle all air cleaner
media. Consult your NBC Officer or NBC NCO for appropriate handling or disposal procedures.
•
NBC contaminated filters must be handled using adequate precautions and must be disposed of by
trained personnel.
•
Wear eye protection when removing filter.
•
Failure to follow these warnings may cause injury to personnel.
Remove air filter (2) from rear of evaporator blower assembly (1) across evaporator coils.
CLEANING AND INSPECTION
Clean and inspect all parts IAW
General Maintenance Instructions
(WP 0014 00).
INSTALLATION
Install air filter (2) across evaporator coils on rear of evaporator blower assembly (1).
END OF WORK PACKAGE
449-051
2
1