TB-9-2350-277-40-P-4

CARRIER, COMMAND POST, FULL-TRACKED, ARMORED, M577A3; STANDARD INTEGRATED COMMAND POST SYSTEM (SICPS), M1068A3

TECHNICAL BULLETIN; INSTALLATION OF CREW II MODIFICATION KIT PART 4 OF 4

JUNE 2009

  TB-9-2350-277-40-P-4 - Page 17 of 100

TB 9-2350-277-40&P-4
INTRODUCTION – Continued
0001 00
0001 00-3
e.
Parts disposition.
Parts removed and not reinstalled are considered excess for TB
application.
Excess parts listed in Table 3 should be discarded IAW AR 725-50 or local
salvage regulations.
Table 3.
Excess Parts to be Discarded
QTY.
NOMENCLATURE
PART NUMBER
CAGE
NSN
1
Loop, Strap, Fastener
10875556
19207
2
Loop, Strap, Fastener
10875599
19207
2
Screw, Cap, Hexagon H
MS35297-60
96906
2
Washer, Flat
MS27183-15
96906
2*
Bolt, Machine
B1821BH038C100L
80204
2*
Washer, Lock
MS35340-46
96906
2*
Washer, Flat
MS27183-14
96906
2*
Nut, Plain, Hexagon
MS35690-522
96906
4*
Washer, Lock
MS45904-72
96906
2*
Screw, Cap, Hexagon H
B1821BH031F100N
80204
3**
Bolt, Machine
B1821BH038C100L
80204
3**
Washer, Lock
MS35340-46
96906
3**
Washer, Flat
MS27183-14
96906
*
M1068A3 Standard Integrated Command Post System (SICPS)
**
M577A3 Command Post Carrier
8.
Special tools, tool kits, jigs, test, measurement, and diagnostic equipment (TMDE); and fixtures
required.
Installation requires common hand and power tools (wrenches, drill, etc.) furnished by
the maintenance shop/contractor.
No special TMDE, jigs, or fixtures are required.
9.
Expendable/durable items list.
See WP 0013 00.
10. Calibration requirements.
No calibration is required.
11. Weight and balance data.
Weight and balance are not affected.
12. Facilities.
No special facilities are required.
No welding is required.


Back to Top