TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 181 of 624

2-165
TB 9-2510-251-13
(1)
Compressor.
a. Connect clutch wire (RD-2-4160-0, black wire with white stripe) to compressor.
b. Route clutch wire over the engine along firewall and through hole in firewall adjacent to
dash panel.
c.
Connect clutch wire to control panel extension (black wire with white stripe).
(2)
Evaporator.
a. Route control panel harness (RD-2-4527-0) to mating connector on evaporator unit
harness.
b. Connect extension harness (RD-4-5958-0) from drier to evaporator unit harness.
c.
Connect power and ground harness to evaporator unit harness.
d. Route wires along edge of transmission tunnel under driver’s side mat.
e. Secure harness to #12 refrigerant hose near top of transmission tunnel.
f.
Cut notch in mat for hose and reinstall screws attaching mat to transmission tunnel.
g. Route wires forward along transmission tunnel, then through grommet and into battery
box.
Figure 2-245.
Routing
2-2.1
Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1
Two-Door with O’Gara Hess Add-on-Armor (Cont’d).
e. Install Electrical Harnesses


Back to Top