TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 172 of 624

2-156
TB 9-2510-251-13
34
34
34
35
35
35
36
36
37
37
32
2-2.1
Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1
Two-Door with O’Gara Hess Add-on-Armor (Cont’d).
b. Install Evaporator and Condenser (Cont’d)
WARNING
Use caution when drilling through floor not to damage or drill into the fuel tank.
Failure to comply may cause injury or death to personnel or damage to equipment.
Figure 2-233. Base Support Bracket
(24) Square base support bracket (32) to floor.
(25) Drill four 3/8 inch (.375) diameter holes, using condenser base support bracket as a guide.
(26) Secure base support bracket (32) to floor with four
bolts (33), washers (34), condenser
support backing plates (35), washers (36), and locknuts (37).
Tighten bolts.
33
33


Back to Top