2-153
TB 9-2510-251-13
(6)
Trim or fold condenser hose drill template as required and align front of template to rear of
armor (2), center holes on rib (3).
(7)
Drill two 1 1/4 inch diameter holes.
De-burr holes.
1
2
3
2-2.1
Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1
Two-Door with O’Gara Hess Add-on-Armor (Cont’d).
b. Install Evaporator and Condenser
Figure 2-228.
Angle Bracket
Figure 2-229.
Drill Template
(1)
Roll rear curtain up and secure.
(2)
Trim or fold evaporator hose drill template as required and place on armor plate angle
bracket (1).
(3)
Drill two 11/16 (.688) diameter holes.
(4)
Drill two 1 1/4 inch diameter holes.
(5)
De-burr holes.
DRILL TEMPLATE