TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 85 of 624

2-69
TB 9-2510-251-13
2-1.2
Installation of Air Conditioning Kit to M1097A2 with GSIE Add-on-Armor (Cont’d).
d. Install Refrigerant Hoses (Cont’d)
Figure 2-103.
Condenser Connection
(15)
Connect Condenser.
a.
Four-door vehicles only:
Lubricate O-ring and install #6 female straight fitting on outlet
(smaller) fitting on condenser.
b.
Two-door vehicles only:
Lubricate O-ring and install #6 female 45° fitting (20) on outlet
(smaller) fitting on condenser.
c.
Lubricate O-ring and install #8 female straight fitting (21) to inlet (larger) fitting on
condenser.
d. Trim ends of #6 hose (22) from drier and connect to right fitting.
e. Trim ends of #8 hose (23) from compressor and connect to left fitting.
(16)
Reinstall plywood panel on top of transmission tunnel by notching around drain hoses and
refrigerant lines.
21
22
20
23


Back to Top