0034-10
TB 9-3950-253-13&P
0034
MIDDLE FRAME SENSOR INSTALLATION – CONTINUED
NOTE
It may be necessary to adjust position of sensor plate in order to activate sensor light.
4. Adjust nut (Figure 13, Item 4) until face of sensor (Figure 13, Item 1) is 0.0625 to 0.1875 in. (2 to 3 mm) from
sensor plate (Figure 13, Item 6).
5. Slide middle frame sensor (Figure 13, Item 1) on bracket (Figure 13, Item 3) toward sensor plate (Figure 13,
Item 6) and identify position where sensor light (Figure 13, Item 5) turns on. Tighten nut (Figure 13, Item 2) at
that position.
6. Return hook arm to stowed position (PLS: TM 9-2320-364-14&P, HEMTT: TM 9-2320-326-14&P).
Figure 13.
Middle Frame Sensor Calibration.
0034
END OF TASK
4
3
2
1
6
5