TM-3-1040-279-12-P

GENERATOR SET, SMOKE, MECHANICAL: PULSE JET, M157 W/120 GAL FOG OIL TANK AND W/80 GAL FOG OIL TANK

TECHNICAL MANUAL; OPERATOR’S AND ORGANIZATIONAL MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST AND DEPOT MAINTENANCE REPAIR PARTS

MAY 1987

  TM-3-1040-279-12-P - Page 249 of 389

TM 3-1040-279-12&P
INSTALLATION
NOTE
If required for your configuration, connect port plugs, thread adapters, 90
degree elbows, etc. to the separator housing and seal male pipe threads with
sealing compound.
1.
Position and install fuel filter/water separator (2) on fog oil tank mounting bracket (10) and secure
with two screws (6), flat washers (7), new lock washers (8), and new self-locking nuts (9).
2.
Connect fuel hose (5) to outlet tube adapter/elbow on fuel filter/water separator (2).
3.
Connect fuel hose (4) to inlet tube adapter/elbow on fuel filter/water (2).
CAUTION
Ensure fuel filter and filter bowl is filled with clean fuel before starting the
M54 Smoke Generator.
Change 4
4-181


Back to Top