4-34. WIRINGHARNESSREPLACEMENT(M870)(continued).
NOTE
Use acid swabbing
brush and denatured alcohol as necessary to clean soldered
connections
during wiring harness splicing procedures.
22.
Injunction box(38),
strip one inch of insulation from new 14-foot black circuit wire (54)and from old circuitwire
(49).
23.
Twist wire ends (55) together and connect circuit wires (49 and 54) using solder and flux.
24.
Tape soldered wire ends (55) with electrical insulation tape.
25.
Pu 11circu it wire (49) from ju nction box (9) while assistant applies grease at junction box (38), until 12 inches of
new circuit wire (54) are left exposed at junction box (38).
26.
Pull circu it wire (49) at junction box (41) wh Heassistant applies grease at junction box (9), until slack is gone.
27.
Cut old circuit wire (49) and wire ends (55) from new circuit wire (54) at junction box (41).
41
C:!5
0
49
49
0
38
e-5
9
65
49
im
4-68