CREW COOLING SYSTEM CHARGING & PURGING PROCEDURES –
CONTINUED
Charging Microclimate Cooling Unit (MCU):
Figure 2-28.
Release Tether for Charging MCU.
1. Connect release tether (2) to umbilical for MCU (1).
Figure 2-29.
Charge/Purge Kit for MCU.
1. Fill one bottle (7) with solution from Section a, step 1.
2. Connect black tube (2) on release tether (1) to black connector (4) on lid (6) of FILLED bottle (7).
3. Connect clear tube (11) on release tether (1) to white connector (10) on lid (9) of EMPTY bottle (8).
4. Connect pump (3) to white connector (5) on lid (6) of FILLED bottle (7).
5. Loosen cap (6) on filled bottle (7) to allow for purging.
TM 5-2350-262-10
Change 7
2-86.9