MALFUNCTION
Table 2-2. Troubleshooting (Continued).
TEST OR INSPECTION
CORRECTIVE ACTION
18.
LEFT CONTROL VALVE LEAKS AT TOP:
Step 1.
Worn packing.
Replace packing (para 2-32).
Step 2.
Circulating in bar at too great pump speed.
Pump speed should not exceed 160 rpm when circulating in bar.
19. INTAKE VALVE LEAKS:
Step 1.
Insufficient spring tension.
Tighten spring on operating shaft (para 2-30).
Step 2.
Scratched or scored valve.
Replace valve (para 2-30).
20. NOZZLE VALVE STUCK OR LEAKS:
Step 1.
Bar pressure seems to keep them tight.
To loosen, rap end of plug stem.
Step 2.
Valves scratched or scored.
Replace valve (para 2-38).
Step 3.
Insufficient clearance between plug and case.
Loosen adjusting nut.