TM 5-4210-249-13&P-3
0328-1
DRAFT
0328
FIELD LEVEL MAINTENANCE
PUMP OPERATOR’S PANEL LIGHT SWITCH REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove two wires (1) from panel light switch (2).
2.
Remove nut (3), washer (4), and panel light switch (2) from pump operator’s panel (5).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00572
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Tags, Identification (WP 0625, Item 51)
References
WP 0615, Fig. 56
Equipment Conditions
Batteries disconnected (TM 9-2320-325-14&P)
Pump operator’s panel housing
opened (WP 0325)