TM 5-4210-249-13&P-3
0331-1
DRAFT
0331
FIELD LEVEL MAINTENANCE
PUMP OPERATOR’S PANEL OVERHEAT TEST BUTTON
INITIAL SETUP:
REMOVAL
1.
Remove two screws (1) and cover plate (2) from pump operator’s panel (3).
NOTE
Tag and mark wires prior to removal to ensure proper installation.
2.
Remove two screws (4), washers (5), and wires (6) from test button (7).
3.
Remove nut (8) and test button (7) from cover plate (2).
4.
Remove nut (9) from test button (7).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00361
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Adhesive, RTV 732 (WP 0625, Item 2)
Tags, Identification (WP 0625, Item 51)
References
WP 0615, Fig. 56
Equipment Conditions
Batteries disconnected (TM 9-2320-325-14&P)
Pump operator’s panel cover opened (WP 0019)