TM 5-4210-249-13&P-3
0331-2
DRAFT
0331
INSTALLATION
1.
Install/adjust nut (9) on test button (7).
2.
Install test button (7) on cover plate (2) with nut (8).
3.
Install two wires (6) on test button (7) with two washers (5) and screws (4).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
4.
Apply electrical sealant to ends of two wires (6) and screws (4).
5.
Install cover plate (2) on pump operator’s panel (3) with two screws (1).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close pump operator’s panel cover (WP 0020)
2.
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE
TFFT00361
WARNING
ICON 30, 44, 27