TM 5-4210-249-13&P-3
0330-1
DRAFT
0330
FIELD LEVEL MAINTENANCE
PUMP OPERATOR’S PANEL MOMENTARY TOGGLE SWITCH REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
•
Pump engine, tank-to-pump, pump cooler, foam tank, and foam system momentary toggle
switches are removed the same way.
•
Pump cooler momentary toggle switch has six wires.
•
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove three screws (1) and wires (2) from pump engine momentary toggle switch (3).
NOTE
Note position of momentary toggle switch and wires prior to removal to ensure proper
installation.
2.
Remove nut (4), washer (5), and pump engine momentary toggle switch (3) from pump operator’s panel (6).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00598
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Adhesive, RTV 732 (WP 0625, Item 2)
Tags, Identification (WP 0625, Item 51)
References
WP 0615, Fig. 56
Equipment Conditions
Batteries disconnected (TM 9-2320-325-14&P)
Pump operator’s panel housing
opened (WP 0325)