TM-5-5420-202-10

LAUNCHER, M48A5 TANK CHASSIS

OPERATOR'S MANUAL

DECEMBER 2009

  TM-5-5420-202-10 - Page 289 of 535

TM 5-5420-202-10
0048
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
WARNING
Leaking fuel could cause a
f re. If fuel leak or exhaust
leak is present, do not operate
personnel heater until repairs
are made. Failure to comply
may result in personnel injury
or death.
NOTE
The M48A5 and M60A2 AVLB
personnel heater locations are
different. The M60A2 AVLB
personnel heater is shown.
21
Before
Personnel
Heater
Figure 23.
M60A2 AVLB Personnel Heater.
a. Check for fuel leaks in area of
quick disconnect at personnel heater,
fittings, and fuel pump.
b. Check for exhaust fumes in area of personnel
heater exhaust pipe at hull feed-through
pipe coupling.
Any fuel leak is
present.
Any exhaust leak is
present.
22
During
Steering
Control
a. Ensure steering control returns to center
position and vehicle does not wander to
right or left.
Vehicle wanders
or steering control
does not center
during operation.
0048-21
Table 1.
PMCS - Continued.


Back to Top