0048
TM 5-5420-202-10
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
12
Before
Air Cleaner
Housings and
Doors (Right
and Left Sides)
Figure 15.
Air Cleaner.
a. Check air cleaner door for cracked,
damaged, or missing mounting hardware.
b. Check for broken or missing door locking
screws.
c. Inspect housing for cracks and dents that
would allow dirt to enter.
d. Check baseplate for cracks.
e. Check door and housing hinges for bent,
broken, cracked, or missing parts.
f. Check blower motor access plate for cracks
and loose or missing mounting bolts.
g. Check that drain plug or inspection plugs are
not loose or missing.
Air cleaner door,
locking screws, or
mounting hardware
is damaged or
missing.
Housing is cracked
or dented.
Door hinges are
broken or bent.
Blower motor
access plate
missing.
Drain or inspection
plugs missing.
0048-14
Table 1.
PMCS - Continued.