0048
TM 5-5420-202-10
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
14
Before
POWER
PLANT
WARNING
LAMP (Engine
Running)
Figure 17.
Powerplant Warning Lamp.
a. Check lamp frequently to ensure it is not
lit. If lamp is lit, immediately check
operator’s indicator panel ENGINE PRESS,
ENGINE TEMP F, TRANSMISSION
PRESS, and TRANSMISSION TEMP F
gauges for abnormal readings.
b. Check that DUST DETECTOR WARNING
LAMP is out. Press lens cap in to check
lamp. If lamp does not light, replace lamp.
If lamp lights, refer to WP 0039.