Change 6
4-414.3
DETAILED TROUBLESHOOTING PROCEDURE
VEHICLE OPERATION – HULL POWER
(Continued)
Symptom-31.1
TM 5-5420-202-20-1
650 AMP ALTERNATOR/REGULATOR IS NOT WORKING - Continued
With engine running, do not disconnect
generator harness at engine disconnect
or bulkhead.
CAUTION
This procedure is to be performed by
two persons. The lead is referred to as
the first technician and shall direct the
activity of the second person called the
second technician.
NOTE
Second Technician (Operator’s Station)
•
Stop engine.
•
Set MASTER BATTERY switch OFF.
First Technician (Commander’s Station)
•
Remove commander’s floor plate (page 17-9).
•
Disconnect harness 12326542 connector (1,
1A, 532, 533, 534) from voltage regulator.
•
Connect “T” harness (page 3-4, Item 38) to
harness 12326542 connector (1, 1A, 532, 533,
534) removed from voltage regulator
.
1
12326542
(1,1A, 532, 533, 534)