4-414.8
Change 6
TM 5-5420-202-20-1
DETAILED TROUBLESHOOTING PROCEDURE
VEHICLE OPERATION – HULL POWER
(Continued)
Symptom-31.1
First Technician (Commander’s Station)
•
Connect red probe of meter to socket F on
bulkhead disconnect harness 12326699 and
black probe to ground.
•
Check if meter indicates 18 to 30 volts dc.
Check for electrical power at pin F of bulkhead
connector.
Does meter indicate 18 to 30 volts dc?
10
NO
YES
•
Repair/replace harness
12326539 (page 10-1).
•
Disconnect “T” harness from
harness 12326542 connector
(1, 1A, 532, 533, 534)
.
•
Connect harness 12326542
connector (1, 1A, 532, 533,
534) to voltage regulator.
•
Replace commander’s floor
plate (page 17-9).
11
12326699