4-414.14
Change 6
TM 5-5420-202-20-1
DETAILED TROUBLESHOOTING PROCEDURE
VEHICLE OPERATION – HULL POWER
(Continued)
Symptom-31.1
First Technician (Commander’s Station)
•
Set multimeter to resistance scale.
•
Connect black probe of meter to "T" harness
socket D and red probe to ground.
•
Check if meter indicates infinite resistance.
Check for shorted diodes in alternator.
Does meter indicate infinite resistance?
24
•
Replace alternator (page 10-1).
•
Connect front accessory
harness 12326539 connector
(CKT 2) to bulkhead disconnect
(page 10-269)
•
Disconnect “T” harness from
harness 12326542 connector (1,
1A, 532, 533, 534)
.
•
Connect harness 12326542
connector (1, 1A, 532, 533, 534)
to voltage regulator.
•
Replace commander’s floor
plate (page 17-9)
25
NO
YES