4-414.16
Change 6
TM 5-5420-202-20-1
DETAILED TROUBLESHOOTING PROCEDURE
VEHICLE OPERATION – HULL POWER
(Continued)
Symptom-31.1
Second Technician (Operator’s Station)
•
Start Engine.
•
Set Idle speed to 750 RPM.
•
Turn OFF all lights, ventilator blowers and
radio equipment.
•
Connect red probe of meter to "T" harness
socket A and black probe socket C.
•
Check if meter indicates 25 to 30 volt dc.
Check CKT 1A at voltage regulator for 25 to 30
volts dc.
Does meter indicate 25 to 30 volts dc?
28
•
Stop Engine.
•
Set FUEL PUMPS switch OFF.
•
Set MASTER BATTERY switch
OFF.
•
Disconnect “T” harness from
harness 12326542 connector (1,
1A, 532, 533, 534)
.
•
Disconnect “T” harness from
voltage regulator.
•
Replace voltage regulator (page
10-1).
29
NO
YES