TM-5-5420-202-20-1

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 1 OF 4

OCTOBER 1985

  TM-5-5420-202-20-1 - Page 626 of 1020

DETAILED TROUBLESHOOTING PROCEDURE
VEHICLE OPERATION – HULL POWER
(Continued)
Symptom-31.1
TM 5-5420-202-20-1
Change 6
4-414.5
Second Technician (Operator’s Station)
Set MASTER BATTERY switch ON.
Set FUEL PUMP switch ON.
First Technician (Commander’s Station)
Connect red probe of meter to "T" harness
socket A (+) and black probe to socket C (-).
Check if meter indicates 18 to 30 volts dc.
Check CKT 1A at voltage regulator for electrical
power.
Does meter indicate 18 to 30 volts dc?
4
NO
YES
See step 59.
Check CKT 1A from connector
at voltage regulator to
connector at master control
panel.
5