TM-5-5420-202-20-1

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 1 OF 4

OCTOBER 1985

  TM-5-5420-202-20-1 - Page 625 of 1020

4-414.4
Change 6
TM 5-5420-202-20-1
DETAILED TROUBLESHOOTING PROCEDURE
VEHICLE OPERATION – HULL POWER
(Continued)
Symptom-31.1
To ensure overvoltage protection circuit
breaker on voltage regulator is in the ON
(UP) position, turn the overvoltage circuit
breaker to the OFF (DOWN) position,
then to the ON (UP) position.
NOTE
NO
YES
Clean and tighten loose
voltage regulator lead
connections.
If connections are not loose,
replace harness 12326542
(page 10-1).
First Technician (Commander’s Station)
Set multimeter to lowest range.
Set circuit breaker on voltage regulator to ON.
Connect “T” harness to voltage regulator.
Connect red probe of meter to "T" harness
socket C and black probe to ground.
Check if meter indicates continuity.
Check continuity from socket C of the test
harness to vehicle chassis (GROUND).
Does meter indicate continuity?
2
3


Back to Top