TM-5-5420-202-20-2

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 2 OF 4

OCTOBER 1985

  TM-5-5420-202-20-2 - Page 294 of 734

TM 5-5420-202-20-2
AIR CLEANER (ARMORED) CENTRIFUGAL FAN POWER LEAD REPLACEMENT (Sheet 1 of 3)
TOOLS:
Slip joint pliers
REFERENCE:
TM 5-5420-202-10
PRELIMINARY PROCEDURES:
Open top grille doors (TM 5-5420-202-10)
Remove air cleaner centrifugal fan cover (page 7-103)
4 .
NOTE
Removal
of
left
or
right
centrifugal fan power lead is the
same. Left side shown.
REMOVAL :
1. Disconnect electrical connector (A).
2.
Push shell (B) back away from contact (C).
3.
Using slip joint pliers, remove washer
(D) from contact (C).
Remove shell (B).
Go on to Sheet 2
7-77


Back to Top