AIR CLEANER (ARMORED) CENTRIFUGAL FAN POWER LEAD REPLACEMENT (Sheet 3 of 3)
2.
3.
4.
5.
6.
7.
8.
9.
10.
adapter.
Install lead (C) through adapter (H). Pull
approximately 10 inches of lead out of
Install shell (J) approximately 2 inches over
end of lead (C) and install washer (K).
Pull shell (J) toward end until it is stopped
by washer (K).
Push gasket (G) and washers (E) and (F)
into adapter (H).
Thread nut (D) onto adapter (H). Use slip
joint pliers and tighten nut.
Install air cleaner centrifugal fan
cover (page 7-105).
Connect electrical connectors (L).
Check operation of air cleaner
(TM 5-5420-202-10).
Close top grille doors (TM 5-5420-202-10).
End of Task
INSTALLATION:
1.
TM 5-5420-202-20-2
Connect two leads (A) and (B) to centrifugal
fan circuit breakers and position the
following parts on lead (C): nut (D), washers
(E) and (F), gasket (G).
7-79