TM 5-5420-202-20-3
MASTER CONTROL PANEL REPAIR (Sheet 38 of 73)
Circuit Breaker Replacement (Sheet 6 of 7)
INSTALLATION; CIRCUIT BREAKER (F):
2.
3.
4.
5.
6.
Place circuit breaker (A) in position on panel.
Using cross-tip screwdriver, install two screws (B) and lock washers (C).
Apply silicone compound to two male electrical connectors on circuit breaker (A).
Using fingers, connect two electrical connectors in rear of circuit breaker (A) by
pushing in.
Position connector (D) to panel.
Using flat-tip screwdriver on screws and
wrench on nuts, install and secure four
screws (E), lockwashers (F), and nuts
(G).
Go on to Sheet 7
TA249016
10-75