POWER/MASTER CONTROL PANEL HARNESS REPLACEMENT (Sheet 8 of 8)
11.
12.
13.
14.
Follow branch of harness assembly (A)
to back side of basket disconnect.
Using spanner wrench, connect bottom
connector (R) (CKT 400, 459, 10) at back
side of basket disconnect.
Install voltage regulator assembly (TM
5-5420-202-20).
Install subfloor access cover under com-
mander’s periscope stowage box (TM
5-5420-202-20).
15.
Install commander’s periscope stowage
box (TM 5-5420-202-20).
16.
Install subfloor access cover under com-
mander’s seat (TM 5-5420-202-20).
17.
Install three battery ground straps (TM
5-5420-202-20).
End of Task
5-82
TM 5-5420-202-20-3