POWER/MASTER CONTROL PANEL HARNESS REPLACEMENT (Sheet 2 of 8)
REMOVAL:
1.
Using spanner wrench, disconnect connector (A) at master relay.
2.
Follow branch of harness assembly (B)
back along voltage regulator mounting
bracket (C).
Go on to Sheet 3
3.
4.
Using 7/16 inch socket, remove screws
(D) and lockwashers (E) securing tops
of two straps (F) that retain harness
assembly (B).
Using spanner and adjustable wrenches,
disconnect connector (G) from intercon-
necting box cable (H).
TM 5-5420-202-20-3
10-296.74
Change 7