TM 5-5420-202-20-4
PERSONNEL HEATER ASSEMBLY REPLACEMENT (Sheet 5
of
5)
9.
Position coupling (Q) and coupling clamp (R) on heater (D).
10.
Close coupling clamp (R) and, using 7/16 inch
to heater (D).
11.
Using torque wrench with extension, tighten
12.
13.
14.
wrench, tighten nut to secure exhaust pipe
clamp (R) nut to 60 lb-ft (81 N-m).
Using flat-tip screwdriver, tighten two clamps (L) securing heater (D) in bracket (K).
Make sure all personnel heater connections,
especially exhaust pipe, are tight and
secure.
Push quick-disconnect coupling (S) into
fuel hose line (T) to connect line to
heater.
15.
Connect harness cable connector (U) to
heater connector (V).
End of Task
All data on pages
18-7 thru 18-14 deleted.
18-6 Change 4